PTC 6 AF Q C EJK A

Home /PTC 6 AF Q C EJK A

Model:PTC 6 AF Q C EJK A

FEATURES
  • 230VAC input, triple output.
  • Conduction base plate cooling.
  • Rugged AC-DC converter for Industrial and Military application.
  • Over voltage, over current & over temp, short circuit protected.
PTC 6 AF Q C EJK A
SPECIFICATIONS
Input
Voltage 230VAC (85 - 264VAC) single phase 50Hz
Current 55A max at 85VAC.
Protection Auto polarity, over current Protection by Internal fuse. U/V (< 84VAC), O/V (>265VAC) recovery auto at nominal range with 5V hysteresis.
Isolation
Input to Output 1000VAC 1minute cutoff current =10mA / 500VDC.20Mῼ
Input to Chassis 1000VAC 1minute cutoff current =10mA / 500VDC.20Mῼ
Output to Chassis 500VAC 1minute cutoff current =100mA / 500VDC.20Mῼ
Environment
Operating Temperature -20 to 50°C internally thermal shutdown protected
Storage Temperature -20°C to 50°C
Relative Humidity 10-90% RH (Non-Condensing)
Cooling Conduction Base plate cooling. If base plate temperature > 85 - 90°C power supply will shut down, recovery auto at <75 - 80°C.
Output
Parameter Output-1 Output-2 Output-3
Voltage 15VDC 50VDC 65VDC
Current 3.3Amp 10Amp 50Amp
Ripple & Noise on PSU connector at 20MHz band with 1uf ceramic at RF Probe. ±1% ±1% ±1%
Power 50W 500W 3250W
Line Regulation on connector Pin ±1% ±1% ±1%
Load regulation on connector Pin ±1% ±1% ±1%
Output V-Adjustment (front panel window pre-set option). Current will be nominal at any voltage range. 10-15VDC 25 -50VDC 45 - 65VDC
Over voltage limit >18VDC >54VDC >68VDC
Over load limit >4.0Amp >12Amp >52Amp
Protection for Individual O/P
O/V, O/C & Short Ckt In case of O/V & O/C Respective Output Voltage should be off and recover auto Hicc-up mode when fault condition remove. Check puls Cycle is 2Sec.
Fault Reporting Fault reporting on serial port.
Voltage Factory Tolerance ±1% of nominal output
Output On / Off Control External LVTTL (3.5VDC) Independent logic for On / Off control. Logic=1 / High (3.5VDC) for On, Logic=0 / Low (0.0VDC) for Off.
RS422 Health Status
Serial Port Serial port RS422 data for input and output health status. Internal PSU temp and independent Output ports voltage and current display in BCD form.
Power Performance
Power Efficiency >87% at full load with input 230VAC
Hold ON Time 20mSec or higher
MTBF 80,000Hrs
Mechanical
Ruggedized Shock, vibration, impact proof
Mounting Base plate mounting
Depth 600mm
Width 175mm with mounting flanges
Height 65mm
Weight (unpacked) < 6.8Kg
Material Base plate Al, Top MS Chrome Plated and powder coated
Connector (Radial Amphenol make)
Input MS3102R-20-15P-SQG (Male)
Input Pins Male 7 Pin for Input
Output, Data & On/off control MS3102R-28-12S-SQG (Female)

26 Pin for Output-1,2,3 & data
IP65 Meet IP65 : In Mating condition only.
Mating Connector Under user scope
Mating Part No Input-MS3106F-20-15S (Female)
Output-MS3106F-28-12P (Male)
Sealing User will take care sealing in mating Pin. Mating connector is include back shell and dust cap with Sealing grommet.
RS422 Communication Protocol

The communication via RS422 interface is based on an AK Protocol. Acknowledgement message

Byte Function
1<STX>
2ignored
3...6 Function code
SXXX.... Control commands
EXXX.... Setting commands
AXXX.... Query commands – AAT0 for Auto data sending
7Blank
8 System and Logic status all, OK – 0, Any type error – 1 (MSB bit - 7)
O/P 1 on / Off status logic, PSU ON – 0, PSU OFF – 1 (bit no 4)
O/P 2 on / Off status logic, PSU ON – 0, PSU OFF – 1 (bit no 3)
O/P 3 on / Off status logic, PSU ON – 0, PSU OFF – 1 (bit no 2)
PSU Over temp. above 90°C – 1, PSU Trip / OFF, below 85°C – 0, PSU OK (bit no 0)
Bit 1, 5, 6 are blank.
9Blank
10O/P 1 - Over voltage status (normal condition= 0 if O/V detect=1)
11O/P 1 - over load status (normal condition=0 if O/L detect =1)
12O/P 2 - over voltage status (normal condition= 0 if O/V detect=1)
13O/P 2 - over load status (normal condition=0 if O/L detect =1)
14O/P 3 - over voltage status (normal condition= 0 if O/V detect=1)
15O/P 3 - over load status (normal condition=0 if O/L detect =1)
16Blank
17Input health status (normal condition= 0 if U/V or O/V detect=1)
18Blank
19O/P1 – Voltage MSB
20O/P1 – Voltage LSB
21Blank
22O/P1 – Current MSB
23O/P1 – Current LSB
24Blank
25O/P2 – Voltage MSB
26O/P2 – Voltage LSB
27Blank
28O/P2 – Current MSB
29O/P2 – Current LSB
30Blank
31O/P3 – Voltage MSB
32O/P3 – Voltage LSB
33Blank
34O/P3 – Current MSB
35O/P3 – Current LSB
36Blank
37..39Temp value O/P in BCD format
40<ETX>
Output Load Current v/s Efficiency
Output-1
Load Current (A) Input Volt. 100V (%) Input Volt. 200V (%) Input Volt. 230V (%)
0.0---
0.869.369.368.4
1.679.079.179.2
2.482.783.583.4
3.284.085.485.4
4.084.386.286.3
4.284.486.386.4
4.684.486.586.6
Output-2
Load Current (A) Input Volt. 100V (%) Input Volt. 200V (%) Input Volt. 230V (%)
0.00---
2.1083.585.685.8
4.2087.189.189.5
6.3088.490.190.7
8.4088.790.891.2
10.5088.690.991.3
11.5588.690.991.3
Output-3
Load Current (A) Input Volt. 100V (%) Input Volt. 200V (%) Input Volt. 230V (%)
0.0---
11.783.285.885.8
23.485.487.387.8
35.085.287.587.9
46.784.687.187.5
58.483.586.486.9
64.282.986.086.5
PDUKE New Products Synqor Products Cosel Products