GHA500F

Home /GHA500F

Model:GHA500F

FEATURES
  • Wattage 500W max.
  • High Power density: 24.1W/inch³.
  • High efficiency 92% typ (Input Voltage 230V, Output Voltage 24V).
  • Conduction cooling.
  • 3″ × 5″ standard footprint.
  • Fits 1U applications.
  • Industrial and Medical safety approvals.
  • Low leakage current.
  • With Remote On/Off (Optional).
  • With AUX1 (12V), AUX2 (5V) (Optional).
  • No minimum load is required.
SPECIFICATIONS
Input
Voltage AC 90–264V, 1 Phase (Output derating is required at AC 90V–115V)
Current ACIN 120V: 5.4A typ.
ACIN 230V: 2.9A typ.
Frequency 50 / 60Hz (47–63Hz)
Power Factor ACIN 120V: 0.95 typ.
ACIN 230V: 0.90 typ.
Inrush Current ACIN 120V: 20A typ.
ACIN 230V: 40A typ.
(Io=100%, At cold start, Ta=25°C)
Leakage Current 0.125 / 0.250mA max (ACIN 120V / 240V 60Hz, Io=100%, According to IEC60601-1)
Environment
Operating Temperature -20°C to +80°C
Operating Humidity 20–90% RH (Non-condensing)
Operating Altitude 3,000m (10,000 feet) max
Storage Temperature -30°C to +80°C
Storage Humidity 20–90% RH (Non-condensing)
Storage Altitude 9,000m (30,000 feet) max
Vibration 10–55Hz, 19.6m/s² (2G), 3 minutes period, 60 minutes each along X, Y and Z axis.
Impact 196.1m/s² (20G), 11ms, once each X, Y and Z axis.
Output
Parameter GHA500F-12 GHA500F-15 GHA500F-24 GHA500F-30 GHA500F-48 GHA500F-56
Max Output Wattage (W) 500.4 501 504 501 504 504
Output Voltage (V) 12 15 24 30 48 56
Forced Air Current (A) 41.7 33.4 21.0 16.7 10.5 9.0
Convection Current (A) 9.2 7.4 4.6 3.7 2.3 1.9
Conduction Cooling Current (A) 16.7 13.4 8.4 6.7 4.2 3.6
Line Regulation (mV) max. 48 60 96 120 192 192
Load Regulation (mV) max. 100 120 150 180 240 240
Ripple (mVp-p), 0 to +50°C 240 240 240 300 300 400
Ripple (mVp-p), -20 to 0°C 320 320 320 400 400 500
Ripple Noise (mVp-p), 0 to +50°C 300 300 300 480 480 500
Ripple Noise (mVp-p), -20 to 0°C 360 360 360 500 500 580
Temperature Regulation (mV), 0 to +50°C 120 150 240 300 480 480
Temperature Regulation (mV), -20 to +50°C 150 180 290 360 600 600
Drift (mV) 48 60 96 120 192 192
Output Voltage Adjustment Range (V) 10.80–13.20 13.50–16.50 21.60–26.40 27.00–31.50 43.20–52.80 52.00–56.00
Output Voltage Setting (V) 12.00–12.48 15.00–15.30 24.00–24.96 30.00–31.20 48.00–49.92 55.00–56.00
Output Timing
Start-up Time 500ms typ. (ACIN 120V, Io=100%)
Hold-up Time 16ms typ. (ACIN 120V, Io=100%)
Efficiency
ACIN 120V GHA500F-12: 88% typ.
GHA500F-15/24/30/48/56: 90% typ.
ACIN 230V GHA500F-12: 90% typ.
GHA500F-15/24/30/48/56: 92% typ.
Protection Circuit and Others
Overcurrent Protection Works over 105% of rating and recovers automatically.
Overvoltage Protection – 12V 13.80–16.80V
Overvoltage Protection – 15V 17.25–21.00V
Overvoltage Protection – 24V 27.60–33.60V
Overvoltage Protection – 30V 34.50–42.00V
Overvoltage Protection – 48V 55.20–67.20V
Overvoltage Protection – 56V 60.00–69.00V
AUX1 (12V, 1A) Optional
AUX2 (5V, 1A) Optional
Remote ON/OFF Optional
Power Good Optional
Isolation
Input–Output–RC–AUX AC 4,000V, 1 minute, cutoff current 10mA; DC 500V, 50MΩ min. (Room Temperature), 2MOPP
Input–FG AC 2,000V, 1 minute, cutoff current 10mA; DC 500V, 50MΩ min. (Room Temperature), 1MOPP
Output–RC–AUX–FG AC 500V, 1 minute, cutoff current 25mA; DC 500V, 50MΩ min. (Room Temperature)
Output–RC–AUX AC 500V, 1 minute, cutoff current 25mA; DC 500V, 50MΩ min. (Room Temperature)
Safety and Agency Approvals
Approvals UL60950-1, ANSI/AAMI ES60601-1, C-UL (CSA60950-1, CAN/CSA60601-1), EN62368-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed.
Noise Regulations
Conducted Noise FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B
Harmonic Attenuator IEC61000-3-2 (Class A)
Mechanical
Case Size (W × H × D) 76.2 × 35 × 127mm
Case Size (inches) 3.0 × 1.4 × 5.0 inches
Weight 420g max.
Cooling Method Convection, Forced air (Require external fan), Conduction cooling
Ordering Information

GH   A   500   F   -OO   -O

1.Series Name
2.Single Output
3.Output Wattage
4.Universal Input
5.Output Voltage
6.Optional Features
Catalogue Notes
  • Derating is required at AC 90V–115V.
  • For dynamic load and input response, please contact the manufacturer.
  • Drift is the change in DC output for an eight-hour period after a half-hour warm-up at 25°C, with input voltage held constant at rated input/output.
  • For harmonic attenuator class options, please contact the manufacturer.
  • Specifications are changed by optional configurations. Refer to the instruction manual.
  • Applicable isolation specifications for AUX and remote control apply when those options are added.
  • Do not operate in an overloaded condition to meet the specifications.
  • Sound noise may be generated by the power supply in case of pulse load.
  • Parallel operation is available with the -P option. Refer to section 5.1 of the instruction manual.
  • Forced air cooling is required to achieve maximum output wattage.
Ordering Information – Optional Features
T3 Mounting hole M3
J1 J.S.T. connector type
J3 Horizontal input connector
R3 With subfeatures (5VAUX, 12VAUX, Remote, Power Good), Molex connector type
P Parallel Operation

Specification is changed at option. Refer to Instruction Manual.

PDUKE New Products Synqor Products Cosel Products