Home /GHA300F-SNF

| Voltage | AC 90–264V, 1 Phase (Output derating is required at AC 90V–115V) |
| Current |
ACIN 120V: 3.3A typ. ACIN 230V: 1.8A typ. |
| Frequency | 50 / 60Hz (47–63Hz) |
| Power Factor (Io=100%) |
ACIN 120V: 0.95 typ. ACIN 230V: 0.90 typ. |
| Inrush Current |
ACIN 120V: 20A typ. ACIN 230V: 40A typ. (Io=100%, At cold start, Ta=25°C) |
| Leakage Current | 0.125/0.250mA max (ACIN 120V/240V 60Hz, Io=100%, According to IEC60601-1) |
| Operating Temperature | -20°C to +70°C |
| Operating Humidity | 20–90% RH (Non-condensing) |
| Operating Altitude | 3,000m (10,000 feet) max |
| Storage Temperature | -30°C to +75°C |
| Storage Humidity | 20–90% RH (Non-condensing) |
| Storage Altitude | 9,000m (30,000 feet) max |
| Vibration | 10–55Hz, 19.6m/s² (2G), 3 minutes period, 60 minutes each along X, Y and Z axis. |
| Impact | 196.1m/s² (20G), 11ms, once each X, Y and Z axis. |
| Parameter | GHA300F-12-SNF | GHA300F-24-SNF | GHA300F-48-SNF |
|---|---|---|---|
| Maximum Output Wattage (W) | 300 | 300 | 302.4 |
| Output Voltage (V) | 12 | 24 | 48 |
| Forced Air Current (A) | 25.0 | 12.5 | 6.3 |
| Line Regulation (mV) max. | 48 | 96 | 192 |
| Load Regulation (mV) max. | 100 | 150 | 240 |
| Ripple (mVp-p), 0 to +50°C | 240 | 240 | 300 |
| Ripple (mVp-p), -20°C to 0°C | 320 | 320 | 400 |
| Ripple Noise (mVp-p), 0 to +50°C | 300 | 300 | 480 |
| Ripple Noise (mVp-p), -20°C to 0°C | 360 | 360 | 500 |
| Temperature Regulation (mV), 0 to +50°C | 120 | 240 | 480 |
| Temperature Regulation (mV), -20°C to +50°C | 150 | 290 | 600 |
| Drift (mV) | 48 | 96 | 192 |
| Start-up Time | 500ms typ. (ACIN 120V, Io=100%) | ||
| Hold-up Time | 16ms typ. (ACIN 120V, Io=100%) | ||
| Output Voltage Adjustment Range (V) | 10.80–13.20 | 21.60–26.40 | 43.20–52.80 |
| Output Voltage Setting (V) | 12.00–12.48 | 24.00–24.96 | 48.00–49.92 |
| Input | GHA300F-12-SNF | GHA300F-24-SNF | GHA300F-48-SNF |
|---|---|---|---|
| ACIN 120V | 88% typ. | 89% typ. | 89% typ. |
| ACIN 230V | 90% typ. | 91% typ. | 91% typ. |
| Overcurrent Protection | Works over 105% of rating and recovers automatically. When output current is more than rated, output will shut down after 5 seconds or more. Recycle input after 3 minutes to reset the protection. |
| Overvoltage Protection – 12V | 13.80–16.80V |
| Overvoltage Protection – 24V | 27.60–33.60V |
| Overvoltage Protection – 48V | 55.20–67.20V |
| AUX1 | 10V, 0.5A |
| AUX2 | 5V, 1A |
| Remote ON/OFF | Possible, AUX2 is available. |
| Power Good | Open collector. |
| Input–Output–RC–AUX | AC 4,000V, 1 minute, cutoff current 10mA; DC 500V, 50MΩ min. (Room Temperature), 2MOPP. |
| Input–FG | AC 2,000V, 1 minute, cutoff current 10mA; DC 500V, 50MΩ min. (Room Temperature), 1MOPP. |
| Output–RC–AUX–FG | AC 500V, 1 minute, cutoff current 25mA; DC 500V, 50MΩ min. (Room Temperature). |
| Output–RC–AUX | AC 500V, 1 minute, cutoff current 25mA; DC 500V, 50MΩ min. (Room Temperature). |
| Approvals | UL60950-1, ANSI/AAMI ES60601-1, C-UL (CSA60950-1, CAN/CSA60601-1), EN62368-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed. |
| Conducted Noise | Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B. |
| Harmonic Attenuator | Complies with IEC61000-3-2 (Class A). |
| Case Size (W × H × D) | 85.2 × 41 × 165.3mm |
| Case Size (inches) | 3.35 × 1.61 × 6.5 inches |
| Weight | 620g max. |
| Cooling Method | Forced air. |
GH A 300 F - OO -SNF O
| 1. | Series Name |
| 2. | Single Output |
| 3. | Output Wattage |
| 4. | Universal Input |
| 5. | Output Voltage |
| 6. | Optional |
| J1 | CN501 PH connector type (J.S.T.) |
| J2 | CN501 Friction locks connector type (Molex) |
EAC-10-472
High voltage pulse noise type: EAP series
Low leakage current type: EAM series
A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply.