| Voltage | AC 90–264V, 1 Phase (Output derating is required at AC 90V–115V) |
| Current |
ACIN 120V: 5.4A typ. ACIN 230V: 2.9A typ. |
| Frequency | 50 / 60Hz (47–63Hz) |
| Power Factor |
ACIN 120V: 0.95 typ. ACIN 230V: 0.90 typ. |
| Inrush Current |
ACIN 120V: 20A typ. ACIN 230V: 40A typ. (Io=100%, At cold start, Ta=25°C) |
| Leakage Current | 0.125 / 0.250mA max (ACIN 120V / 240V 60Hz, Io=100%, According to IEC60601-1) |
| Operating Temperature | -20°C to +80°C |
| Operating Humidity | 20–90% RH (Non-condensing) |
| Operating Altitude | 3,000m (10,000 feet) max |
| Storage Temperature | -30°C to +80°C |
| Storage Humidity | 20–90% RH (Non-condensing) |
| Storage Altitude | 9,000m (30,000 feet) max |
| Vibration | 10–55Hz, 19.6m/s² (2G), 3 minutes period, 60 minutes each along X, Y and Z axis. |
| Impact | 196.1m/s² (20G), 11ms, once each X, Y and Z axis. |
| Parameter | GHA500F-12 | GHA500F-15 | GHA500F-24 | GHA500F-30 | GHA500F-48 | GHA500F-56 |
|---|---|---|---|---|---|---|
| Max Output Wattage (W) | 500.4 | 501 | 504 | 501 | 504 | 504 |
| Output Voltage (V) | 12 | 15 | 24 | 30 | 48 | 56 |
| Forced Air Current (A) | 41.7 | 33.4 | 21.0 | 16.7 | 10.5 | 9.0 |
| Convection Current (A) | 9.2 | 7.4 | 4.6 | 3.7 | 2.3 | 1.9 |
| Conduction Cooling Current (A) | 16.7 | 13.4 | 8.4 | 6.7 | 4.2 | 3.6 |
| Line Regulation (mV) max. | 48 | 60 | 96 | 120 | 192 | 192 |
| Load Regulation (mV) max. | 100 | 120 | 150 | 180 | 240 | 240 |
| Ripple (mVp-p), 0 to +50°C | 240 | 240 | 240 | 300 | 300 | 400 |
| Ripple (mVp-p), -20 to 0°C | 320 | 320 | 320 | 400 | 400 | 500 |
| Ripple Noise (mVp-p), 0 to +50°C | 300 | 300 | 300 | 480 | 480 | 500 |
| Ripple Noise (mVp-p), -20 to 0°C | 360 | 360 | 360 | 500 | 500 | 580 |
| Temperature Regulation (mV), 0 to +50°C | 120 | 150 | 240 | 300 | 480 | 480 |
| Temperature Regulation (mV), -20 to +50°C | 150 | 180 | 290 | 360 | 600 | 600 |
| Drift (mV) | 48 | 60 | 96 | 120 | 192 | 192 |
| Output Voltage Adjustment Range (V) | 10.80–13.20 | 13.50–16.50 | 21.60–26.40 | 27.00–31.50 | 43.20–52.80 | 52.00–56.00 |
| Output Voltage Setting (V) | 12.00–12.48 | 15.00–15.30 | 24.00–24.96 | 30.00–31.20 | 48.00–49.92 | 55.00–56.00 |
| Start-up Time | 500ms typ. (ACIN 120V, Io=100%) |
| Hold-up Time | 16ms typ. (ACIN 120V, Io=100%) |
| ACIN 120V |
GHA500F-12: 88% typ. GHA500F-15/24/30/48/56: 90% typ. |
| ACIN 230V |
GHA500F-12: 90% typ. GHA500F-15/24/30/48/56: 92% typ. |
| Overcurrent Protection | Works over 105% of rating and recovers automatically. |
| Overvoltage Protection – 12V | 13.80–16.80V |
| Overvoltage Protection – 15V | 17.25–21.00V |
| Overvoltage Protection – 24V | 27.60–33.60V |
| Overvoltage Protection – 30V | 34.50–42.00V |
| Overvoltage Protection – 48V | 55.20–67.20V |
| Overvoltage Protection – 56V | 60.00–69.00V |
| AUX1 (12V, 1A) | Optional |
| AUX2 (5V, 1A) | Optional |
| Remote ON/OFF | Optional |
| Power Good | Optional |
| Input–Output–RC–AUX | AC 4,000V, 1 minute, cutoff current 10mA; DC 500V, 50MΩ min. (Room Temperature), 2MOPP |
| Input–FG | AC 2,000V, 1 minute, cutoff current 10mA; DC 500V, 50MΩ min. (Room Temperature), 1MOPP |
| Output–RC–AUX–FG | AC 500V, 1 minute, cutoff current 25mA; DC 500V, 50MΩ min. (Room Temperature) |
| Output–RC–AUX | AC 500V, 1 minute, cutoff current 25mA; DC 500V, 50MΩ min. (Room Temperature) |
| Approvals | UL60950-1, ANSI/AAMI ES60601-1, C-UL (CSA60950-1, CAN/CSA60601-1), EN62368-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed. |
| Conducted Noise | FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B |
| Harmonic Attenuator | IEC61000-3-2 (Class A) |
| Case Size (W × H × D) | 76.2 × 35 × 127mm |
| Case Size (inches) | 3.0 × 1.4 × 5.0 inches |
| Weight | 420g max. |
| Cooling Method | Convection, Forced air (Require external fan), Conduction cooling |
GH A 500 F -OO -O
| 1. | Series Name |
| 2. | Single Output |
| 3. | Output Wattage |
| 4. | Universal Input |
| 5. | Output Voltage |
| 6. | Optional Features |
| T3 | Mounting hole M3 |
| J1 | J.S.T. connector type |
| J3 | Horizontal input connector |
| R3 | With subfeatures (5VAUX, 12VAUX, Remote, Power Good), Molex connector type |
| P | Parallel Operation |
Specification is changed at option. Refer to Instruction Manual.