RA-R-300-DE-S-B

Home /RA-R-300-DE-S-B

Model:RA-R-300-DE-S-B

FEATURES
  • Dual-Redundant unit with natural air Cooling.
  • 110VDC Input / 5.0VDC/30A Redundant Output.
  • Input transients & surge protected.
  • Rugged DC / DC Converter for Railway applications.
  • Over-voltage / short-circuit / Over-current / Over-temp. protected.
RA-R-300-DE-S-B
SPECIFICATIONS
Input A & B
Voltage 110VDC (110 to 250VDC)
Current 1.7A Max.
Isolation HV Input-Earth : 2KVAC, 50Hz-60sec cut off current 50mA.
Input-Output : 2KVAC, 50Hz-60sec cut off current 50mA.
Output-Earth : 500VAC, 50Hz-60sec cut off current 50mA.
Isolation Resistance Input-Earth : 2KVAC, 50Hz-60sec cut off current 50mA.
Input-Output : 2KVAC, 50Hz-60sec cut off current 50mA.
Output-Earth : 500VAC, 50Hz-60sec cut off current 50mA.
Environmental
Operating Temperature -20°C to +70°C
Storage Temperature -20°C to +75°C
Relative Humidity 20-90% RH (Non-Condensing)
Cooling Internal forced air Cooling.
Output
Parameter Specification
Factory Set Voltage 5.0VDC±0.5VDC
Current 30A
Power 150W Dual Redundant
Ripple (mVp-p) <100mVpk-pk
Line Regulation <=1% of Vnom.
Load Regulation <=1% of Vnom.
LED Indications Input (Red), PS-1, 2 OK (Green), PS-1, 2 Fault (Red), Output (Green)
Over-Voltage Protection Protection operative at ≤ 5.8VDC.
O/P protection Over-load, Short-circuit, Over-Voltage, Over-current, Over-temp protected.
O/P Voltage Adj. ±0.5V adjustment provided at Independent O/P.
Relay contact Provided C to No (Open-Fault, Close-Ok).
Test points Provided for check the PS-1 / PS-2 voltage during desired final Output Vadj.
Redundancy Output Redundancy and line drop compensation provided for two units by internal feed back loop and crowbar compensation.
Efficiency >84% at full load (Exclusive OR-ing Diode power)
STANDARDS (conformance)
Vibration 10-55Hz,19.6m/s2 (2G)
Impact 196.1m/s2 (20G), 11ms, Once each X, Y, & Z.
Agency Approvals UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN.
Conducted Noise Complies with FCC-B, VCCI-B, CISPR22-B, EN55011, EN55022.
Harmonic Attenuator Complies with IEC61000-3-2 class A.
Mechanical
Mounting 19" Rack mounting
Depth 305mm
Width 482.6mm (19" Rack mounting)
Height 67mm (1.5U)
Weight (unpacked) 4.5Kg Approx.
Connector
Input 3 Pin male screw lock type include mating
PFC 4 Pin male screw lock type include mating
Output 4 Pin TB-56 screw Terminal.
Instruction for DR & PS Operation
a) Adjust the output voltage-1 to second place of decimal after switch off of Output Voltage-2. Monitor the output voltage on test points-1 at front panel.
b) Increase the load to 50% and 100% and note values Vo;;xx xx volts as desired.
c) Adjust the output voltage-2 to second place of decimal after switch off of Output Voltage-1. Monitor the output voltage on test points-2 at front panel .
d) Increase the load to 50% and 100% than note values Vo;;xx xx volts as desired.
e) Ensure that the two are matching with each other, as close as possible
f) connect the load at combined Output connector